¿Cómo monitoreo remotamente el voltaje del panel posterior de un chasis PXI?
Muchos chasis PXI de National Instruments soportan monitoreo remoto CompactPCI de voltaje e inhibición a través de un Subconector D macho de 9 pines, nombrado DB9, localizado en el panel posterior. Estos chasis son los de la serie PXI-104x, PXI-1052, y PXIe-1062. Para saber si su chasis soporta monitoreo y control de voltaje, refiérase a su manual.
La siguiente tabla muestra la distribución de pines de la inhibición remota y monitoreo de voltaje para los modelos mencionados arriba. Otros modelos de chasis pueden tener distintas conexiones.
D-Sub Pin (104x, 1052, 1062) |
Señal |
1 |
Tierra Lógica |
2 |
+5 VDC |
3 |
Reservado |
4 |
+3.3 VDC |
5 |
Inhibir(Activo Bajo) |
6 |
+12 VDC |
7 |
Reservado |
8 |
-12 VDC |
9 |
Tierra Lógica |
Puede usar la señal de inhibición (activo bajo) para deshabilitar el chasis. Para deshabilitar remotamente el chasis, conecte el pin inhibidor (pin 5) a un pin de Tierra Lógica (pin 1 o 9). Mientras exista esta conexión, el chasis permanecerá apagado (en estado de espera); cuando remueva esta conexión, el chasis se encenderá.