在更新NI-RIO之后,为什么我不能够和我的USRP设备通信?



主要软件: Driver Software>>NI-RIO
主要软件版本: 1.3
主要软件修正版本: 14.0
次要软件: N/A
硬件: Modular Instruments>>RF Measurement Devices>>NI Software Defined Radio>>NI USRP-2950R, Modular Instruments>>RF Measurement Devices>>NI Software Defined Radio>>NI USRP-2952R, Modular Instruments>>RF Measurement Devices>>NI Software Defined Radio>>NI USRP-2953R, Modular Instruments>>RF Measurement Devices>>NI Software Defined Radio>>NI USRP-2940R, Modular Instruments>>RF Measurement Devices>>NI Software Defined Radio>>NI USRP-2943R, Modular Instruments>>RF Measurement Devices>>NI Software Defined Radio>>NI USRP-2942R

问题: 我最近更新了NI-RIO驱动到版本14.0,但是下载我不能够在PCIe上使用NI-USRP的API函数和我的USRP设备通信。为什么我不能够和我的设备通信?

解答:

在NI-USRP 1.3和NI-RIO 14.0之间有不兼容问题,会阻止使用NI-USRP的API函数利用PCIe总线进行通信。设备可能在MAX仍然能够找到。

NI-USRP 1.3只能和NI-RIO 13.1.1兼容。如果你有NI-USRP 1.3和NI-RIO 14.0同时安装,有两个选择。第一,你可以更新到NI-USRP 14.0,将会解决这个兼容性的问题。其它选项是卸载NI-RIO 14.0,然后重新安装NI-RIO 1.3驱动(这个选项使用LabVIEW 2014并不推荐)。



相关链接:

附件:





报告日期: 08/12/2014
最近更新: 01/03/2015