使用高速数字I/O板卡来判断数字线信号在设定的电压范围内。
硬件: Digital I/O (DIO)>>High-Speed Digital I/O>>PXI-6542, Digital I/O (DIO)>>High-Speed Digital I/O>>PXI-6551, Digital I/O (DIO)>>High-Speed Digital I/O>>PXI-6552, Digital I/O (DIO)>>High-Speed Digital I/O>>PXI-6561, Digital I/O (DIO)>>High-Speed Digital I/O>>PXI-6562, Digital I/O (DIO)>>High-Speed Digital I/O>>PCI-6541, Digital I/O (DIO)>>High-Speed Digital I/O>>PCI-6542, Digital I/O (DIO)>>High-Speed Digital I/O>>PCI-6551, Digital I/O (DIO)>>High-Speed Digital I/O>>PCI-6552, Digital I/O (DIO)>>High-Speed Digital I/O>>PCI-6561, Digital I/O (DIO)>>High-Speed Digital I/O>>PCI-6562, Digital I/O (DIO)>>High-Speed Digital I/O>>PXI-6541
问题: 是否可能使用高速数字I/O板卡来判断数字线信号在设定的电压范围内?
解答: 可以。但是仅限于655x系列板卡。654x和656x系列不支持这种功能。
可以通过niHSDIO Configure Data Interpretation VI来实现。您需要把VI的输入参数配成"Valid or Invalid"。当采集的电压在设定的范围内时,返回值为1。反之,则为0。可以参考下面的图片。
高低门限电压值可以通过niHSDIO Configure Voltage VI.来设定。
相关链接:
附件:
报告日期: 08/04/2006
最近更新: 08/04/2006
文档编号: 3OEDQP9N