Measurement & Automation Explorer에서 장비 목록에 장비가 나타나지 않습니다.



주요한 소프트웨어:
주요한 소프트웨어 버전: 4.5
문제가 해결된 소프트웨어 버전: N/A
부차적인 소프트웨어: N/A
하드웨어: Reconfigurable I/O (RIO)>>R Series>>PCI-7831R, Reconfigurable I/O (RIO)>>R Series>>PXI-7811R, Reconfigurable I/O (RIO)>>R Series>>PCI-7813R, Reconfigurable I/O (RIO)>>R Series>>PXI-7813R, Reconfigurable I/O (RIO)>>R Series>>PXI-7834R, Reconfigurable I/O (RIO)>>R Series>>PXI-7830R, Reconfigurable I/O (RIO)>>R Series>>PXI-7833R, Reconfigurable I/O (RIO)>>R Series>>PXI-7831R, Reconfigurable I/O (RIO)>>R Series>>PCI-7830R, Reconfigurable I/O (RIO)>>R Series>>PCI-7833R, Reconfigurable I/O (RIO)>>R Series>>PCI-7811R

문제점:

NI Software중 일부분을 업그레이드 한 이후에, Measurement & Automation Explorer(MAX)에 특정 장비가 보이지 않는 것을 확인했습니다. 어떻게 하면 장비를 목록에 나타나게 할 수 있으며, 설정을 어떻게 해야 합니까?



솔루션:

NI PXI Platform Service 2.5.2 및 NI-VISA 4.5.1 이전 버젼을 설치할 경우 VISA 기반의 PCI/PXI 장비가 Measurement & Automation Explorer(MAX)에서 사라질 수 있게 할 수 있습니다.   R-Series의 보드 및 Timing and Synchronization 보드와 VISA 기반의 3rd party PCI/PXI 장비 경우에도 영향을 미칠 수 있습니다. 이러한 장비를 통해 개발된 어플리케이션의 경우 이전과 같이 정상적으로 동작하게 됩니다.  또한 윈도우 장치 관리자에서도 정상적으로 인식이 됩니다.

아래 표의 경우 서로 영향을 받는 하드웨어와 소프트웨어의 목록을 보여줍니다. 필요에 따라서 솔루션에 있는 드라이버로 업그레이드를 진행하시면 됩니다.



관련 링크: KnowledgbeBase 4FE9HEUI:Why is my RIO Device Not Showing up in MAX under PXI System?