DAQmx计数器输出:脉冲发送完成属性



硬件: Multifunction DAQ (MIO)>>M Series>>PXI-6284, Multifunction DAQ (MIO)>>M Series>>PCI-6221, Multifunction DAQ (MIO)>>M Series>>PCI-6224, Multifunction DAQ (MIO)>>M Series>>PCI-6229, Multifunction DAQ (MIO)>>M Series>>PCI-6250, Multifunction DAQ (MIO)>>M Series>>PCI-6251, Multifunction DAQ (MIO)>>M Series>>PCI-6254, Multifunction DAQ (MIO)>>M Series>>PXI-6221, Multifunction DAQ (MIO)>>M Series>>PCI-6259, Multifunction DAQ (MIO)>>E Series>>PCI-6023E, Multifunction DAQ (MIO)>>E Series>>PCI-6024E, Multifunction DAQ (MIO)>>E Series>>PCI-6025E, Multifunction DAQ (MIO)>>E Series>>PCI-6031E, Multifunction DAQ (MIO)>>E Series>>PCI-6032E, Multifunction DAQ (MIO)>>E Series>>PCI-6034E, Multifunction DAQ (MIO)>>E Series>>PCI-6035E, Multifunction DAQ (MIO)>>E Series>>PCI-6036E, Multifunction DAQ (MIO)>>E Series>>PCI-6040E (PCI-MIO-16E-4), Multifunction DAQ (MIO)>>E Series>>PCI-6052E, Multifunction DAQ (MIO)>>E Series>>PCI-6053E, Multifunction DAQ (MIO)>>E Series>>PCI-6071E, Multifunction DAQ (MIO)>>E Series>>PCI-MIO-16E-1, Multifunction DAQ (MIO)>>E Series>>PXI-6023E, Multifunction DAQ (MIO)>>E Series>>PXI-6024E, Multifunction DAQ (MIO)>>E Series>>PXI-6025E, Multifunction DAQ (MIO)>>E Series>>PXI-6030E, Multifunction DAQ (MIO)>>E Series>>PXI-6032E, Multifunction DAQ (MIO)>>E Series>>PXI-6033E, Multifunction DAQ (MIO)>>E Series>>PXI-6035E, Multifunction DAQ (MIO)>>E Series>>PXI-6040E, Multifunction DAQ (MIO)>>E Series>>PXI-6052E, Multifunction DAQ (MIO)>>E Series>>PXI-6053E, Multifunction DAQ (MIO)>>E Series>>PXI-6070E, Multifunction DAQ (MIO)>>E Series>>PXI-6071E, Multifunction DAQ (MIO)>>M Series>>PCI-6280, Multifunction DAQ (MIO)>>M Series>>PCI-6281, Multifunction DAQ (MIO)>>M Series>>PCI-6284, Multifunction DAQ (MIO)>>M Series>>PXI-6224, Multifunction DAQ (MIO)>>M Series>>PXI-6229, Multifunction DAQ (MIO)>>M Series>>PXI-6250, Multifunction DAQ (MIO)>>M Series>>PXI-6251, Multifunction DAQ (MIO)>>M Series>>PXI-6254, Multifunction DAQ (MIO)>>M Series>>PXI-6259, Multifunction DAQ (MIO)>>M Series>>PXI-6280, Multifunction DAQ (MIO)>>M Series>>PXI-6281, Multifunction DAQ (MIO)>>M Series>>PXI-6289, Multifunction DAQ (MIO)>>M Series>>PCI-6289, Multifunction DAQ (MIO)>>M Series>>PXI-6225, Multifunction DAQ (MIO)>>M Series>>PCI-6225, Multifunction DAQ (MIO)>>M Series>>PCIe-6251, Multifunction DAQ (MIO)>>M Series>>PCIe-6259

问题: 我正在实现一个有限点的可重触发的脉冲序列生成功能。有没有方法能够在每一个触发周期(即重复周期)脉冲发送完毕的时候返回通知?

解答:

可以的。计数器输出的通道属性节点中有PulseDone的属性,能够返回一个布尔量来显示有限点脉冲序列的发送是否完成。

这个属性节点仅仅当脉冲序列的一个周期结束的时候才返回一个值。当他被读取一次的时候,属性就被自动地重设为



相关链接:

附件:





报告日期: 01/24/2006
最近更新: 01/07/2008
文档编号: 3TNBEMRM