在cRIO上部署声音与振动的应用出错



硬件: CompactRIO>>Controllers>>cRIO-9012

问题:

我对我的应用进行Order分析,当我部署了一个应用到设备时,我得到了如下的错误:“Failed to Download OAT Frequency Shift (Mixer).vi or LabVIEW:Failed to load shared Library Order.Out: OatFreqShiftH:E on ET target device.

 

 

为什么会得到如下错误,并且我该如何排查呢?



解答:

这个错误是因为声音与振动工具包并没有安装在设备上,为了减少这些错误,打开MAX。在MAX种,扩展远程系统“栏,点击设备标识符旁的”加号“。右键点击软件标签,并且选择添加和删除软件。当你选择这些特性来安装到你的远程设备上,确保包含了声音与振动工具包。接着安装软件安装的引导向导来完成安装步骤。

安装完声音与振动工具包到远程设备后,重新部署该应用程序。这个错误信息应该会消失。




相关链接: DeveloperZone Tutorial: 10 Questions to Ask When Selecting Your Sound and Vibration Measurement System 