为什么在labview Real-Time 2011中打开FlexRIO主界面库VI时会有一个破损的箭头?



硬件: Reconfigurable I/O (RIO)

问题:

FlexRIO主界面库VI包含许多FlexRIO开发者在其应用中使用到的实用VI和函数。该库对FlexRIO适配模块(FAMs)发送和接受信息十分有用。在labview2011中一个小改动破坏了该库和Real-Time应用程序的兼容性。



解答:

解决这个兼容性问题,需要将您现有的GetDefaultBitfileFromDeviceName.vi 版本用本文附件中的版本替换。

文件在以下目录中:

Windows 32-bit
C:\Program Files\National Instruments\LabVIEW 2011\vi.lib\LabVIEW Targets\FPGA\FlexRIO\Tools\GetDefaultBitfileFromDeviceName.vi

Windows 64-bit
C:\Program Files (x86)\National Instruments\LabVIEW 2011\vi.lib\LabVIEW Targets\FPGA\FlexRIO\Tools\GetDefaultBitfileFromDeviceName.vi



相关链接: DeveloperZone: LabVIEW 2011 FPGA Module Known Issues