如何在ARINC和1553设备中找到MTBF数据?



硬件: CompactDAQ>>Analog Input Modules>>NI 9237

问题: 如何在ARINC和1553设备中找到MTBF(平均错误时间)数据?

解答:

平均错误时间计算的更多信息可以在 MIL-STD-217F Ground Benign, Fixed, and Mobile conditions 中找到,采取+25摄氏度环境下测试。

Product Ground Benign
Ground Fixed
Ground Mobile
ACX429-3U-4 67500
19000
5800
ACX429-3U-8
65500
18800
5700
ACX429-3U-16
60500
17800
5500
ACX1553-3U-1 66180 17420 5440
ACX1553-3U-1-DS 53700 15060 4960
ACX1553-3U-2 61160 16470 5180
ACX1553-3U-2-DS 50020 14330 4760
ACX1553-3U-4 51200 14200 4600
ACX1553-6U-1 65060 17240 5370
ACX1553-6U-1-DS 52960 14930 4910
ACX1553-6U-2 60200 16300 5120
ACX1553-6U-2-DS 49380 14200 4700
ACX1553-6U-4 39030 10850 3560



相关链接: AIM 1553 LabVIEW Instrument Driver
MIL-STD-217F Handbook

附件:





报告日期: 06/02/2010
最近更新: 08/02/2013
文档编号: 5A19LEW8