Al cargar un VI de LabVIEW en TestStand utilizando el Run-Time Engine obtengo el siguiente error.
Error 0: Unable to load VI VI_name with the Run-Time Engine. It is possible that the version of the VI or one of its subVIs is not the same as the LabVIEW Run-Time Engine version.
El VI que estoy intentando cargar fue creado con la misma versión que el Run-Time Engine. ¿Qué puedo hacer para evitar este error?
Este error puede ocurrir al intentar cargar un VI que se encuentra en una biblioteca de LabVIEW mientras se utiliza el Run-Time Engine. Si se obtiene este error, guarde la biblioteca de LabVIEW junto con el VI que está intentando cargar. Esto debe resolver el problema.
|