From Friday, April 19th (11:00 PM CDT) through Saturday, April 20th (2:00 PM CDT), 2024, ni.com will undergo system upgrades that may result in temporary service interruption.

We appreciate your patience as we improve our online experience.



¿Por Qué Recibo un Error de Run-Time Version en TestStand al Cargar un VI?



Software Primario:
Versión de Software Primario: 1.0
Versión de Software Primario Corregido: N/A
Software Secundario: LabVIEW Run-Time Engine, LabVIEW Development Systems>>LabVIEW Full Development System, LabVIEW Development Systems>>LabVIEW Base Package, LabVIEW Development Systems>>LabVIEW Professional Development System

Problema:

Al cargar un VI de LabVIEW en TestStand utilizando el Run-Time Engine obtengo el siguiente error.

Error 0: Unable to load VI VI_name with the Run-Time Engine. It is possible that the version of the VI or one of its subVIs is not the same as the LabVIEW Run-Time Engine version.

El VI que estoy intentando cargar fue creado con la misma versión que el Run-Time Engine. ¿Qué puedo hacer para evitar este error?



Solución:

Este error puede ocurrir al intentar cargar un VI que se encuentra en una biblioteca de LabVIEW mientras se utiliza el Run-Time Engine. Si se obtiene este error, guarde la biblioteca de LabVIEW junto con el VI que está intentando cargar. Esto debe resolver el problema.



Ligas Relacionadas:

Archivos Adjuntos:





Día del Reporte: 09/14/2007
Última Actualización: 02/10/2009
Identificación del Documento: 4DDFK9V3