ハードウェア: PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers, PXI/CompactPCI>>Controllers

問題:
NI 9476 DOモジュールを24V電源に接続しました。ロード()が何も接続されていない状態でOff状態の出力を見ると0Vではなく8Vとなってしまいます。これは正常な動作なのでしょうか。

解決策:
これは正常な動作です。NI 9476は高電圧で動作するICチップを搭載しています。このICチップが、ロード(負荷デバイス)が接続されていない時には、Off状態でも8V出力してしまうことが原因です。0Vの出力を行いたい場合は、マニュアルに記載されているようにデバイス(ロード/負荷デバイス)を接続する必要があります。この接続を行うことで、DO端子がCOM端子をリファレンスとすることになり、Off状態(電流が流れていない状態)で0Vを 読み取ることが可能となります。