在使用LabVIEW 6.1的Remote Panels控制時,為何會出現"The Connection with Server Has Been Broken"錯誤訊息?



主要軟體:
主要軟體版本: N/A
主要軟體修正版本: N/A
次要軟體:

問題: 我所寫的程式在發展環境執行時並無問題,且我啟動LabVIEW網頁伺服器Web Server (Tools>>Options...>>Web Server: Configuration)

為了在Remote Panels下測試我的VI程式,我在遠端電腦打開瀏灠器,並輸入我的VI所在正確URL位址.此VI在瀏灠器中顯示若干秒後,即產生以下錯誤訊息"The Connection with the Server has been broken"?


解答: 你可以在你程式VI迴圈中加入一等待(wait)功能解決此問題.例如加上Wait Until Next MS Multiple.vi(Function Pallette>>Time&Dialog>>Wait Until Next MS Multiple VI),參數值可設為10ms.

相關連結:

附加檔案:





報告日期: 05/15/2002