使用NI-4461的模拟输入和模拟输出时产生错误-50103。
硬件: Modular Instruments>>Dynamic Signal Acquisition and Analysis (DSA)>>PXI-4461
问题: 当使用Multi-Device Sync-AI and AO-Shared Timebase & Trig-DSA例子,或者同步4461的模拟输出和模拟输入时,出现如下错误:
Error -50103: The specified resource is reserved. The operation could not be completed as specified.
为什么出现该错误?如何处理?
解答: 在NI-DAQmx的8.3和8.5版本中,这是一个已知问题:在NI-4461上同步模拟输入和模拟输出时会出现该错误。在8.6及以后的版本中解决了该问题。
通过下面的链接可以下载NI-DAQmx的最新版本。
相关链接: Drivers and Updates: NI-DAQmx Download PageNI-4461 Product Page
附件:
报告日期: 11/20/2007
最近更新: 11/20/2012
文档编号: 4FJA904C