將VI載入至TestStand以Run-Time Engine來執行時,會產生VI Version的錯誤



主要軟體:
主要軟體版本: 1.0
主要軟體修正版本:
次要軟體: LabVIEW Run-Time Engine, LabVIEW Development Systems>>LabVIEW Full Development System, LabVIEW Development Systems>>LabVIEW Base Package, LabVIEW Development Systems>>LabVIEW Professional Development System

問題:

當我將LabVIEW VI使用Run-time Engine來作載入的動作時,會得到下面的錯誤訊息:

Unable to load VI '[VI name]' with the Run-Time Engine. It is possible that the version of the VI or one of its subVIs is not the same as the LabVIEW Run-Time Engine version.

這個VI和Run-time Engine的版本是ㄧ致的,為什麼會有這樣的錯誤訊息呢?



解答: 如果您要將尚未存檔的LabVIEW library其中的VI作載入的動作,就會出現這樣的錯誤。只要將LabVIEW library作存檔的動作即可解決這樣的問題。