硬件: Multifunction DAQ (MIO)
问题: 当我在Measurement and Automation Explorer中为我的PCI板卡运行自检时,提示错误
50151
。
Error 50151: The firmware - which is software resident on a device - has entered an unknown state usually as a result of a cascade failure induced by an unexpected series of state inputs. The operation could not be completed as specified, and you should immediately terminate all further transactions if you are able to do so.
解答: 为了解决这个问题,您必须将该板卡插到5V的PCI插槽中。.
当前大部分National Instruments的PCI设备都支持5V PCI和3.3V PCI-X标准,但是一些早期的PCI设备需要使用5V的PCI插槽。如果您将早期的5V PCI设备插到3.3V的插槽,并在Measurement and Automation Explorer中运行自检,您就会得到错误50151。
相关链接: KnowledgeBase 2N2DBOH5: Will a National Instruments PCI Board Work in a PCI-X Bus?