Steps to Install the LabVIEW 6.1 Real-Time and DSC 6.1 ModulesPrimary Software: LabVIEW Modules>>DSC ModulePrimary Software Version: 6.1 Primary Software Fixed Version: N/A Secondary Software:
Problem: The following document contains some recommendations for the LabVIEW Datalogging and Supervisory Control module and LabVIEW Real-Time Module installations. It also links to known installation issues. Solution: LabVIEW 6.1 can co-exist with any previous version of LabVIEW. The same applies to DSC and RT modules. However, you cannot mix LabVIEW, DSC or RT 6.1 versions with 6.0.x versions. All versions have to be the same in order to work together. For example, you cannot install DSC 6.0.2 version on the top of LabVIEW 6.1 version. For information about running different versions of RT modules on the same computer refer to the Installing Software on RT series PXI hardware knowledge base in the related links. Beware that only one proxy (or VI-Based server) can be active at a time. Each DSC version installs its own copy of the proxy VIs that won't work with any other version. For example, there are 6.0.2 and 6.1 version installed, but only one OPC Proxy can be registered - suppose the 6.0.2 version is registered. This means that you'll only be able to connect to an OPC server from 6.0.2 version. Connection attempt from 6.1 version will generate an error. For more information refer to the Why Do I Get "Unable to Launch XYZ. Error when loading XYZ Proxy..." on a DSCEngine Launch? knowledge base in the related links. If you are using FieldPoint IAS server you need to upgrade to FieldPoint 3.0.1. This is not neccessary if you are using the OPCFieldPoint or Logos protocol. For more information refer to the Unable to Launch FieldPoint after Upgrading to the LabVIEW DSC Module 6.1 knowledge base in the related links. If you plan to uninstall LabVIEW 6.0.x and keep only the latest 6.1 version, do so before you start the 6.1 installation! We recommend using the default installation, unless it is necessary to run a custom installation. Beware when doing a custom install, there are dependencies between the application components. For example, if you choose not to install the LabVIEW Advanced Analysis Library, you won't be able to run most of the LabVIEW DSC examples. If you select the custom installation and decide to make some edits in the Feature Tree, then pay special attention to the description of the action set for the edited feature. There are 4 actions you can set for each item: install it, leave it installed, leave it uninstalled or uninstall it. Check the picture below for an illustrative example. Recommended installation steps:
Related Links: KnowledgeBase 2HEEPEZ8: Installing Software on RT Series PXI Hardware KnowledgeBase 2GU91LJ6: Why Do I Get "Unable to Launch XYZ. Error when loading XYZ Proxy..." on a DSC Engine Launch? KnowledgeBase 2H1F3EJ6: Unable to Launch FieldPoint after Upgrading to the LabVIEW DSC Module 6.1 Attachments: Example of a Feature Tree. In this case, the LabVIEW 5.0.1 Support will be installed, the 5.1 support will remain uninstalled, the 6.0 support will be uninstalled and the 6.1 support will remain installed.
Report Date: 01/08/2002 Last Updated: 06/20/2002 Document ID: 2H7FAOJ6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||