Windows 3.1 Support For Data Acquisition (DAQ) Devices
Primary Software: Driver Software>>NI-DAQ
Primary Software Version: 5.0.5
Primary Software Fixed Version: N/A
Secondary Software: N/A
Hardware: Legacy DAQ Devices
Problem: What DAQ Devices are supported under Windows 3.1 and what NI-DAQ version can I use?
Solution: Use one of the following versions of NI-DAQ for DAQ devices supported under Windows 3.1.
- NI-DAQ 4.6.1f5 - This is the final version to support the NI Lab-PC.
- NI-DAQ 4.9.0f1 - This is the final version to support the NI AT-A2150, NI DSP-2200, and NI EISA-A2000 boards.
- NI-DAQ 5.0.5 - This is the final version supported under Windows 3.1. See the following table for a list of supported DAQ devices.
| Devices Supported Under Windows 3.1 and NI-DAQ 5.0.5 |
| Plug and Play ISA/PC/AT |
| E Series AT Multifunction DAQ Family (Product Name) |
| NI-6011E (NI AT-MIO-16-XE-50), NI 6020E (NI AT-MIO-16E-10), NI 6021E (NI AT-MIO-16DE-10), NI 6030E (NI AT-MIO-16XE-10), NI 6032E (NI AT-AI-16XE-10), NI 6060E (NI AT-MIO-16E-2), NI 6061E (NI AT-MIO-64E-3), NI 6070E (NI AT-MIO-16E-1) |
| PC Multifunction DAQ |
| NI Lab-PC-1200, NI Lab-PC-1200AI, NI PC-LPM-16PNP, NI PC-516 |
| Analog Output |
| NI PC-AO-2DC |
| Digital Input/Output |
| NI AT-6533, NI PC-DIO-24PNP, NI PC-DIO-96PNP, NI PC-OPDIO-16 |
| Computer-Based Instruments |
| NI AT-5411 |
| Legacy ISA/PC/AT |
| AT Multifunction DAQ |
| NI AT-MIO-16DH-25, NI AT-MIO-16DH-9, NI AT-MIO-16DL-25, NI AT-MIO-16DL-9, NI AT-MIO-16F-5, NI AT-MIO-16H-15, NI AT-MIO-16H-25, NI AT-MIO-16H-9, NI AT-MIO-16L-15, NI AT-MIO-16L-25, NI AT-MIO-16L-9, NI AT-MIO-16X, NI AT-MIO-64F-5, NI AT-MIO-64F-3 |
| PC Multifunction DAQ |
| NI Lab-PC+, NI PC-LPM-16 |
| Analog Output |
| NI AT-AO-10, NI AT-AO-6 |
| Digital Input/Output |
| NI AT-DIO-32F, NI PC-DIO-24, NI PC-DIO-96 |
| Counter/Timers |
| NI PC-TIO-10 |
| PCI |
| E Series Multifunction DAQ Family (Product Name) |
| NI 6011E (NI PCI-MIO-16-XE-50), NI 6030E (NI PCI-MIO-16XE-10), NI 6040E (NI PCI-MIO-16E-4), NI 6070E (NI PCI-MIO-16E-1) |
| Digital Input/Output |
| NI 6508 (NI PCI-DIO-96), NI 6533 (NI PCI-DIO-32HS) |
| Legacy Multifunction DAQ |
| NI PCI-1200 |
| DAQCard (PCMCIA) |
| E Series Multifunction DAQ Family (Product Name) |
| NI 6041E (DAQCard-AI-16E-4), NI 6012E (DAQCard-AI-16XE-50) |
| Analog Output |
| NI DAQCard-AO-2DC |
| Digital Input/Output |
| NI DAQCard-DIO-24 |
| Computer-Based Instruments |
NI DAQCard-4050 Note:Supported only in LabVIEW (4.x or Earlier), Lab/CVI (4.x or Earlier) Easy I/O, and by Instrument Drivers. There is no NI-DAQ API support for this product. |
| Legacy DAQCards |
| NI DAQCard-1200, NI DAQCard-500, NI DAQCard-516, NI DAQCard-700 |
| DAQPad (Parallel Port) |
| NI DAQPad-1200, NI DAQPad-6011E (DAQPad-MIO-16XE-50) |
| VXI |
| NI VXI-AO-48XDC, NI VXI-MIO-64E-1, NI VXI-MIO-64XE-10, NI VXI-SC-1000, VXI-SC-1102, NI VXI-SC-1150 |
| SCXI |
| SCXI-1100, SCXI-1102, SCXI-1120/D, SCXI-1121, SCXI-1122, SCXI-1124, SCXI-1140, SCXI-1141, SCXI-1160, SCXI-1161, SCXI-1162/HV, SCXI-1163/R, SCXI-1000, SCXI-1000DC, SCXI-1001 Chassis, Remote SCXI-2000, SCXI-2400, SCXI-1200 |
| Signal Conditioning Accessories |
| SC-2040, SC-2042-RTD, SC-2043-SG, AMUX-64T |
|
Related Links: Drivers and Downloads: NI-DAQ Version 5.0.5 for Windows 3.1/95/NTDrivers and Downloads: NI-DAQ Version 4.9.0f1 for Windows 3.1/95/NTDrivers and Downloads: NI-DAQ Version 4.6.1f5 for DOS/Windows 3.1/95/NTCurrent NI-DAQ Driver Version SupportData Acquisition SupportKnowledgeBase 1XIDBB2L: What Changes Were Made in the Various Versions of NI-DAQ for Windows?
Attachments:
Report Date: 04/14/2003
Last Updated: 05/02/2008
Document ID: 2WDELSK8
|
|