Can I Use a BNC-2090 and an SCXI Chassis on the Same DAQ Card?Hardware: Multifunction DAQ (MIO)>>Connector Blocks>>BNC-2090
Problem: I currently have a system built with a BNC-2090 connected to my DAQ card. I'm adding the capability now to read in just a few thermocouples and I have an SCXI chassis and an 1102 lying around. Can I use my BNC-2090 to get my basic analog inputs and use my SCXI 1102 for my thermocouples while still using only the single DAQ card? Solution: While not a reccommended solution, you can use both a BNC-2090 and an SCXI system at the same time. To do this connect your DAQ card to the BNC-2090 with a standard 68 pin cable. Then connect the SCXI chassis to your BNC-2090 with another 68 pin cable. Since the two 68 pin ports on the BNC-2090 are connected in parallel, the signals from the SCXI chassis can just pass through the BNC-2090. There are a few caveats when using your hardware in this way that you should be aware of.
Related Links: Attachments:
Report Date: 06/26/2006 Last Updated: 06/30/2006 Document ID: 3YPB0ACW |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||