Changing the Maximum Number of Buffers for the 1408 in MAXPrimary Software: Driver Software>>Vision Acquisition SoftwarePrimary Software Version: 2.0 Primary Software Fixed Version: N/A Secondary Software: Driver Software>>NI-IMAQ Hardware: Image Acquisition (IMAQ)>>Analog Image Devices>>PCI-1408
Problem: When I try to change the Maximum Number of Buffers in the Tools » IMAQ path of the Measurement & Automation Exporer (MAX), the number always reverts to 50. Solution: Make sure that you have administrative privileges before changing this parameter. If you are able to change the Maximum Number of Buffers, but receive an IMG_ERR_MXBF error when you try to acquire, follow the link below.
Related Links: KnowledgeBase 20LG25U9: "IMG_ERR_MXBF - too many buffers already allocated" Error When Trying to Acquire an Image Attachments:
Report Date: 05/06/2002 Last Updated: 05/09/2007 Document ID: 2L5AF99D |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||