Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
This Document is not yet Rated  Rate this Document

Internal Software Error with LabVIEW FPGA Module and CVS 1450 Series

Primary Software: LabVIEW Modules>>FPGA Module
Primary Software Version: 1.1
Primary Software Fixed Version: N/A
Secondary Software: Vision Development Module

Problem:
When I compile my FPGA code on the 1450 Series Compact Vision System, I get the following error:

An internal software error in LabVIEW FPGA Module has occured. Please contact National Instruments technical support at ni.com/support with the following information:

Directory specified by the FPGASourceFilesDirectoryPath resource file tag does not exist.

Directory path: C:\Program Files\National Instruments\LabVIEW X.Y\Targets\NI\FPGA\IMAQIO\FPGAFiles





Solution:
This problem occurs when the order of installation in incorrect. You should install the Vision software only after installing the FPGA Module. If you did not install the components in the right order, reinstalling the Vision software will fix the compilation error.

Related Links:
NI Developer Zone: LabVIEW FPGA Support for NI CVS-1450 Series Compact Vision System

Attachments:





Report Date: 03/31/2009
Last Updated: 04/03/2009
Document ID: 4VUA99WQ

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit