This VI is Not Executable Error When Running ExecutablePrimary Software: LabVIEW Run-Time EnginePrimary Software Version: 8.2 Primary Software Fixed Version: N/A Secondary Software: N/A
Problem: I have a LabVIEW executable that will run on some Windows computers but not others. When trying to run the executable, I receive the error This VI is not executable. I have installed the correct version of LabVIEW Run-Time Engine and all necessary drivers. What is the cause of this error? Solution: The cause of this is often an outdated version of the .NET framework on the non-development computer. To resolve the issue, you should upgrade .NET framework to at least the version that is installed on the development machine. You can check which version of .NET is installed by going to Start » Control Panel » Add or Remove Programs. You can download the current version of .NET framework from Microsoft's website. Related Links: LabVIEW 8.6 Help: Developing Applications that Use a Previous Version of .NET KnowledgeBase 3UEACE4P: Requirements for Running a LabVIEW Executable that Uses .NET Assemblies Attachments:
Report Date: 11/05/2008 Last Updated: 02/13/2009 Document ID: 4R4GA1FS |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||