Switching Between Calibrated Fixed-Point and Raw Integer Modes for CompactRIO I/OHardware: CompactRIO>>Analog Input Modules, CompactRIO>>Analog Output Modules
Problem: How can I select either calibrated fixed-point or raw integer data types for the I/O nodes of my C-Series module? Solution: With LabVIEW 8.5 or later and NI-RIO 2.4 or later, this can be done by changing the Calibration Mode (Raw or Calibrated) in the properties of the C Series module. This can be done in the Project Explorer window by right-clicking the module and selecting Properties:
Related Links: KnowledgeBase 4JNCQO4H: What Units Are Returned from C Series Analog Modules when using Fixed-Point Data? Developer Zone Tutorial: Using NI CompactRIO Scan Mode with NI LabVIEW Software Attachments:
Report Date: 05/06/2008 Last Updated: 12/12/2008 Document ID: 4L5B754H |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||