Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
This Document is not yet Rated  Rate this Document

Which IAK File Does LabVIEW Use to Get Information Regarding My FieldPoint Configuration?

Primary Software: LabVIEW Development Systems>>Professional Development System
Primary Software Version: 8.0
Primary Software Fixed Version: N/A
Secondary Software: N/A
Hardware: Compact FieldPoint

Problem:
How do I know which IAK file is being accessed in LabVIEW when communicating with my FieldPoint hardware?

Solution:
IAK files store all of the configuration information for FieldPoint hardware.  The IAK file that LabVIEW uses to access your FieldPoint configuration depends on how you're using LabVIEW (Project Explorer, VI or executable) and which FieldPoint VI you're using to communicate with your hardware (IO Control, Get Configuration, or Legacy VIs). The table below describes which IAK file is accessed in each situation.

  Project Explorer Stand  Alone VI VI as an EXE
FieldPoint IO VI IAK file associated with the project IAK file that was last opened IAK file distributed with the EXE
FieldPoint Get Configuration Info VI IAK file associated with the project IAK file that was last opened IAK file distributed with the EXE
Other legacy VIs (FieldPoint Open, FieldPoint Create Tag, FieldPoint Read, FieldPoint Write, etc.) IAK file that was last opened IAK file that was last opened IAK file that was last opened


Related Links:
KnowledgeBase 2MOC6RM9: Applying FieldPoint IAK Settings to a FieldPoint Real-Time Controller

Attachments:





Report Date: 05/07/2008
Last Updated: 05/08/2008
Document ID: 4L6D42T2

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit