Problems Using SH68-68-D1 Cable With an E or M Series Device and SCXI Chassis? Hardware: Compact FieldPoint>>Connector Blocks
Problem: I have an SH68-68-D1 cable connecting my SCXI chassis to an E or M Series Data Acquisition (DAQ) board. The chassis is not detected in Measurement and Automation Explorer (MAX), but everything else seems to be installed correctly. What's wrong with my setup? Solution: The SH68-68-D1 is similar to the SH68-68-EP, but it is dedicated for use with the following boards.
To verify that the correct cable is being used, check the assembly number. The SH68-68-D1 has a "183432-0x" assembly number, while the SH68-68-EP has a "184749-0x" assembly number. For more information on cabling issues, contact a National Instruments Technical Representative at the link below. Related Links: Product Manuals: 6533 and 6534 User Manual for Traditional NI-DAQ Product Manuals: PCI/PXI-6703/6704 User Manual Product Manuals: SCXI Chassis User Manual and Specifications Product Manuals: E Series User Manual Product Manuals: M Series User Manual Attachments:
Report Date: 12/31/2002 Last Updated: 10/07/2008 Document ID: 2SUCAEBS |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||