CANopen LabVIEW Library Error CodesPrimary Software: Driver Software>>NI-CANPrimary Software Version: 2.2 Primary Software Fixed Version: N/A Secondary Software: N/A
Problem: I'm using the CANopen LabVIEW Library and I'm getting an error code that I don't recognize. How can I tell what that error code means? Solution: The CANopen LabVIEW Library installs a text file with all of the CANopen specific error codes. This text file can be found at <Program Files>\National Instruments\LabVIEW x.x\user.lib\errors\CANOPEN-ERRORS.TXT. The CANopen error codes are also included below. Error codes for the CANopen VIs error code="5376" Invalid CANopen object reference. Object does not exist. error code="5377" Invalid CANopen object reference. Object has the wrong type. error code="5378" An SDO transfer is already pending for this device. A device cannot handle more than one SDO transaction at a time. Related Links: Product Page: CANopen LabVIEW Library Attachments:
Report Date: 11/28/2007 Last Updated: 11/28/2007 Document ID: 4FRHGQYW |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||