Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
This Document is not yet Rated  Rate this Document

OPCDemo.exe Not Registered Properly on a Deployed System

Primary Software: Measurement Studio>>Enterprise Edition (Full Development System)
Primary Software Version: 7.1
Primary Software Fixed Version: N/A
Secondary Software: N/A

Problem: If you deploy the OPC client example on a machine and run the installer under a privilege other than Administrator, the OPC client example throws an error when the example attempts to connect to the OPCDemo server.

When you click connect to OPC Server you receive the following error in Status.
Error: Can't connect to OPC Server. Server not found. Make sure that it is installed and registered correctly.

Solution: The project is attached below. For the OPC client example to correctly connect to the OPCDemo server, complete the following steps:
  1. Run the installer with the Administrator privilege.

  2. In the Installer dialog box, select For Everyone instead of Just Me.



Related Links:

Attachments:


CPlusPlusDataSocket.zip


Report Date: 10/07/2005
Last Updated: 10/10/2005
Document ID: 3Q3966HW

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit