Problem: I am using the X & mR Chart VI, which computes chart limits. When I change the standard error multiplier input, my limits do not change on the control chart. I am using the Draw Chart with Zones VI to produce the control chart.

Solution: The Draw Chart with Zones VI produces charts with zone lines, not control limit lines. Three zones, A, B and C correspond to upper and lower 3 , 2 and 1 standard error control limits, respectively. These zones lines shift only if the standard error changes. The standard error multiplier does not affect the lines. To view the change in control limits by altering the standard error multiplier, use the Draw Control Chart VI.