Why Do I Get Error -70183 When Starting a Move With NI SoftMotion Controller for CANopen? Hardware: Motion Control>>Controllers>>NI SoftMotion Controller for CANopen
Problem: I can initialize the NI SoftMotion Controller. I can see the position update in 1D Interactive in Measurement and Automation Explorer (MAX). But, when I try to start a move, I get Error -70183 (NIMC - dataTransmissionError). What could be causing this? Solution: The drive is not configured to run in CANopen mode. This is a setting in the CME basic setup. To change to CAN mode in CME 2, select Amplifier»Basic Setup. Then change Position Loop Input to CAN. Related Links: Getting Started: NI SoftMotion Controller for Copley Controls CANopen Drives 2.0 AE KB 3X7HRFS4: Cannot Add Axes to NI SoftMotion Controller Attachments:
Report Date: 10/17/2006 Last Updated: 10/18/2006 Document ID: 42GG3OFL |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||