Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
This Document is not yet Rated  Rate this Document

Failed to Load Shared Library NILVSim.* on a Real-Time Target Device

Primary Software: LabVIEW Modules>>Real-Time Module
Primary Software Version: 2009
Primary Software Fixed Version: N/A
Secondary Software: N/A

Problem:
When trying to run a VI on my real-time target I see the message: Deployment completed with errors.
When I look back the error message specified is: Failed to load shared library NILVSim.*.

Solution:
This problem can occur when your real-time application uses the Control Design and Simulation module, but this module is not installed on the controller. Use Measurement and Automation Explorer to install the Control Design and Simulation module on the controller.

Please refer to  KnowledgeBase 2HGDNOT4: Failed to Load Shared Library *.* on Real-Time Target Device for more comprehensive information on this problem.

Related Links:
KnowledgeBase 2HGDNOT4: Failed to Load Shared Library *.* on Real-Time Target Device

Attachments:





Report Date: 05/05/2009
Last Updated: 05/06/2009
Document ID: 4X4AMSMK

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit