The NI PXI-5600 RF Downconverter Does Not Show up in Measurement and Automation Explorer (MAX) on the Real-Time (RT) Target When Using NI-DAQmx 8.7.

Primary Software: Driver Software>>NI-RFSA
Primary Software Version: 2.0.7
Primary Software Fixed Version: N/A
Secondary Software: N/A

Problem:
If a customer installs NI-DAQmx 8.7 and then NI-RFSA 2.0.7, RT support for the NI PXI-5600 won't work (i.e. the NI PXI-5600 will not be recognized as a device) without an additional step.

Solution:
After downloading NI-RFSA 2.0.7 to their RT target, the customer will need to redownload NI-DAQmx to the RT target. After rebooting the RT system, the NI 5600 should appear in MAX.