Order Analysis Example Projects for Sound and Vibration Assistant 7.0 and Non-English Operating SystemsPrimary Software: Sound and Vibration Measurement SuitePrimary Software Version: 7.0 Primary Software Fixed Version: N/A Secondary Software: N/A
Problem: I am using the Sound and Vibration Assistant version 7.0 on a Non-English operating system. When I open an order analysis example project the data view does not display any signals. Solution: This issue will be fixed in Sound and Vibration version 8.0. As a workaround you must manually reconnect the order analysis step outputs to the the data view. Simply click on a step output that you wish to see and drag it onto the data view. When you run the project, your signals will be visibile from the data view. このページの日本語版は、こちらのリンクをクリックしてください。 Related Links: Attachments:
Report Date: 12/03/2008 Last Updated: 12/11/2008 Document ID: 4S2B5O7E |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||