How Can I Change the Digital I/O Logic Levels on a NI 6535/6536/6537?Primary Software: LabVIEW Development Systems>>LabVIEW Professional Development SystemPrimary Software Version: 8.6.1 Primary Software Fixed Version: N/A Secondary Software: Driver Software>>NI-DAQmx Hardware: Digital I/O (DIO)>>High-Speed>>PXIe-6536, Digital I/O (DIO)>>High-Speed>>PXIe-6537
Problem: I am trying to send and read data from my DUT which operates at 3.3 V. I would like to change the logic level for my NI 6535/36/37 such that a logic high is set to 3.3 V. How can I change the logic family for my digital I/O task in DAQmx? Solution: Most DAQmx digital I/O boards are made to use with 5 V TTL logic levels. However, some hardware have the capability for a user to change the logic levels to user-defined values such as the NI 6535/36/37 family. In order to do this in LabVIEW you can use a DAQmx Channel property node and use the property Digital Input » Logic Family or Digital Output » Logic Family as shown in Figure 1. ![]() Figure 1: DAQmx Channel Property Node DI.LogicFamily Not all DAQmx devices allow users to change the logic levels of the digital channels. The property will not be visible if a device which supports this functionality is not present in your system.
Related Links: Product Manual: NI 6535/6536/6537 Attachments:
Report Date: 04/01/2009 Last Updated: 12/28/2009 Document ID: 4W0FNJJQ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||