How Do I Convert Relative Time Data to Absolute Time Data in DIAdem?

Primary Software: DIAdem
Primary Software Version: 10.0
Primary Software Fixed Version: N/A
Secondary Software: N/A

Problem:
By default, DIAdem maintains time data as the number of seconds elapsed since 01/01/0000.  How do I change this value to a more absolute representation?

Solution:
DIAdem provides a function called RTT( ) which accepts a relative time value and then converts it to a particular date and time.  Optionally, it also accepts a second parameter for formatting the date and time that it returns.  More information about the RTT( ) function can be found in the DIAdem help document.

Related Links:
KnowledgeBase 3O74I9F: Converting Excel Date/Time Values to DIAdem Values
KnowledgeBase 3BR3KOFN: Why do date/time data created in LabVIEW have an offset in DIAdem?