Error -61024 from Open FPGA VI Reference VI Primary Software: LabVIEW Modules>>FPGA ModulePrimary Software Version: 1.1 Primary Software Fixed Version: 1.1 Secondary Software: Driver Software>>NI-RIO Hardware: Reconfigurable I/O (RIO)
Problem: My host VI returns error -61024 from the Open FPGA VI Reference node. Why is this happening? Solution: This is most likely due to a version conflict between your RIO and VISA drivers. If you have VISA 3.3 you must have RIO 1.3 or later. You can determine your driver version in Measurement and Automation Explorer (MAX). If you have RIO 1.2 or earlier you will not see NI-RIO in MAX and you must upgarde to RIO 1.3. After trying the above steps, you still get the same error, try the following troubleshooting steps:
Related Links: NI-RIO Version 1.3.1 for Windows 2000/XP-- for R Series (and Embedded Upgrade) Attachments:
Report Date: 07/19/2005 Last Updated: 12/30/2005 Document ID: 3NI9SMJ4 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||