Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
This Document is not yet Rated  Rate this Document

Missing Samples in Data View of Signal Express From a Continuous Acquisition

Primary Software: LabVIEW SignalExpress>>Development System
Primary Software Version: 3.0
Primary Software Fixed Version: N/A
Secondary Software: N/A

Problem:
In the data view of my continuous acquisition only a portion of my view is filled with data.  How can I see a larger block of data in one view?



Solution:
After acquiring a continuous signal in SignalExpress and viewing that signal in playback mode only data of the current block size is displayed no matter what the x axis of the scale is.  In order to change this you can go to the Playback Options tab and set the "Block Size (samples)" to a larger value and then up to that size will be displayed on the Data View.



Related Links:
Knowledge Base 467BQDSF: How to Display SignalExpress Data with History
Knowledge Base 4SFJTTLY: Displaying a Second Y-Axis in LabVIEW SignalExpress

Attachments:





Report Date: 04/03/2009
Last Updated: 04/07/2009
Document ID: 4W2E073Z

Your Feedback! poor Poor  |  Excellent excellent   Yes No