Do I need to Install Support for Shared Variable on TPC-2012? Primary Software: LabVIEW Modules>>Touch Panel ModulePrimary Software Version: 1.0 Primary Software Fixed Version: N/A Secondary Software: LabVIEW Modules>>Touch Panel Module Hardware: Industrial Communications>>HMI and Industrial PC>>TPC-2006
Problem: I have an application using shared variables developed to run on TPC-2012. However, the install option on the project explorer is only available for ARM-based processor. How do I install support for shared variable on TPC-2012? Solution: The TPC-2012 is an x86-based processor and comes with preinstalled support for shared variable. Hence, you do not need to install support for shared variable on TPC-2012. If you install support for shared variable using the (ARM) option, then each time you power on or reboot the TPC-2012, it will always prompt to keep or replace the existing installation files. These files include the nitaglvpda.dll, lkdynamic.dll, lksec.dll and lksock.dll. To remove this installation,
Related Links: Attachments:
Report Date: 03/01/2007 Last Updated: 03/12/2007 Document ID: 4708HD2M |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||