I Cannot Scan My SCXI-1200 Channels and Other Module Channels SimultaneouslyPrimary Software: LabVIEW Development Systems>>Full Development SystemPrimary Software Version: 4.1 Primary Software Fixed Version: N/A Secondary Software: N/A Hardware: SCXI>>Modules>>SCXI-1200
Problem: When trying to put SCXI-1200 channels in one element of a channel string array and other module channels in another element of the channel string array, LabVIEW returns errors. (Group Too Large for instance). Solution: The SCXI-1200 is controlled in the same way as a plug in board so that you cannot scan the board channels and an SCXI module channel in the same scan. Related Links: Attachments:
Report Date: 10/12/1994 Last Updated: 05/11/2004 Document ID: 02BG0DIE |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||