Problem:
Traditional NI-DAQ automatically sets the optimal gains for my SCXI module based on the input limits I specify. How can I check these gain values?

Solution:
You can retrieve the gain value set by Traditional NI-DAQ by using the AI Parameter VI after using the AI Config VI to set the input limits of the signal. Wire the operation input to a value of "Get", and wire the parameter name input to a constant of "SCXI Gain". The gain currently set for the SCXI module is returned from the float out output.

Related Links:
KnowledgeBase 21CDIA4U: Distribution of Gain Between an SCXI Module and an E Series Data Acquisition (DAQ) Device
Developer Zone Example Program: Obtaining Gain Applied by the Entire System, DAQ, SCXI for a Channel in an SCXI System