Test 2 of Hardware Diagnostics Fails After Using GPIB-1014Hardware: GPIB>>Plug-in Controllers>>GPIB-1014
Problem: Why does Test 2 of the hardware diagnostics fails after the 1014 has been used? Solution: Test 2 tests the DIR register. The DIR is not cleared upon a RESET, so if the 1014 has accepted data, then it will FAIL the test. If you are seeing this problem, do not include this test in the hardware diagnostic routine. Related Links: Attachments:
Report Date: 08/22/1997 Last Updated: 10/15/2006 Document ID: 10L707QA |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||