Is There Any Way to Read MAX Motion Parameters Using LabVIEW? Primary Software: Driver Software>>NI-Motion/FlexMotionPrimary Software Version: 7.0 Primary Software Fixed Version: N/A Secondary Software: LabVIEW Development Systems>>Base Package Hardware: Motion Control, Motion Control>>Controllers
Problem: I would like to read the encoder steps per revolution and counts per revolution (and PID parameters) that have been set in MAX using LabVIEW so that I can perform other calculations using them. Is there a VI to do this? Solution: A number of parameters that are set in MAX are not readable in LabVIEW. This encoder setting is one of them. Other examples include the PID control loop parameters, stepper loop mode, and the axis filter settings. These parameters can, however, be loaded using LabVIEW VIs. Once those values have been loaded, they can be used elsewhere in the application by using property nodes or by wiring the values to other VIs. Related Links: Developer Zone: Motion Control Support Initializing Motion Parameters Attachments:
Report Date: 09/10/2004 Last Updated: 07/27/2007 Document ID: 3D9BGIB1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||