Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
This Document is not yet Rated  Rate this Document

SCXI_ModuleID_Read Returns Error in Trad DAQ 7.x

Primary Software: Driver Software>>NI-DAQ
Primary Software Version: 4.6.1
Primary Software Fixed Version: N/A
Secondary Software: LabWindows/CVI Development Systems>>Full Development System

Problem:

Using Traditional NI-DAQ 7.x, I am getting an unexpected result after calling:

SCXI_ModuleID_Read(SCXIchassisID, moduleSlot, ModuleID)

This function used to work fine when I had an older version of Traditional NI-DAQ (Version 6.9.3 or older) but now the return value is -1. The help says that the communication path is likely broken. What is wrong?



Solution:

This is a known issue that was introduced in NI-DAQ 7.0. You can work around it by adding a call to SCXI_Load_Config(SCXIchassisID).



Related Links:

Attachments:





Report Date: 03/02/2007
Last Updated: 03/05/2007
Document ID: 471G5U7E

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit