Why does my Compact Vision System (CVS) 145x Not Appear in MAX?

Primary Software: Driver Software>>NI-IMAQ for IEEE-1394
Primary Software Version: 2.0.2
Primary Software Fixed Version: N/A
Secondary Software: Utility Software>>Measurement & Automation Explorer, Vision Builder for Automated Inspection

Problem:
I have an NI Compact Vision System (CVS) 145x and I do not see it when I look under Remote Systems in Measurement & Automation Explorer (MAX).  When I use Vision Builder for Automated Inspection or LabVIEW, the CVS is identified. Why is my CVS not appearing in MAX?

Solution:
Check the following when troubleshooting your NI CVS 145x in MAX:
  • Verify that the same version of the NI-IMAQ for IEEE 1394 driver is installed on your system as on your CVS. The NI-IMAQ for IEEE 1394 driver is required for MAX to identify the CVS system under Remote Systems. If you have an older driver on your PC than is on the CVS, MAX will not recognize the CVS.

  • Verify that no other remote devices have the same IP address as the CVS.

  • Verify that power is being supplied to the CVS system by checking the Power LED.

  • If you are connecting to the CVS through the network, try connecting directly to the CVS using a crossover cable, then refresh MAX and see if the CVS now appears.

  • Connect a monitor to the CVS to see if its IP address responds.

  • Reboot the CVS into safemode and again refresh MAX.

  • If you know the IP address of the CVS, you can try to add the CVS manually as a Remote System by doing the following:
    1. Right-Click on Remote Systems in MAX.
    2. Select Create New...
    3. Select Remote Device (not on the local subnet) as shown below.
    4. Enter the IP address of the CVS.


Related Links:
Products & Services: Vision Acquisition Software
KnowledgeBase 3409ILOK: How Do I FTP to the Compact Vision System (CVS 145x)?
KnowledgeBase 3FBHAIB1: Vision Builder for Automated Inspection Installer FAQ
KnowledgeBase 36O8QMHW: CVS-1454 Product Notification: Critical BIOS Update For Compact Vision System

Attachments:


addCVS.GIF


Report Date: 12/08/2003
Last Updated: 02/08/2008
Document ID: 347A1HA2