Linker Error on Multiple Builds in a LabVIEW Blackfin Project

Primary Software: LabVIEW Modules>>Embedded Module for Blackfin Processors
Primary Software Version: 2.5
Primary Software Fixed Version: N/A
Secondary Software: N/A

Problem:
I am getting a linker error on the third or fourth build in a LabVIEW Blackfin Project. What do I do?

Solution:
For some LabVIEW Blackfin Projects, the linker throws an error if the same Build Specification is used multiple number of times. This issue is limited to a few types of Project files. There are two work arounds as mentioned below
  • Delete the old Build Specification and make a new one or
  • Delete the Folders created by the build process. The folder is by default created in the Project Directory and is named after the Project.