Can I Install Real-Time on my PXIe-8130 Controller?

Primary Software: LabVIEW Modules>>Real-Time Module
Primary Software Version: 8.5
Primary Software Fixed Version: N/A
Secondary Software: N/A
Hardware: PXI/CompactPCI>>Controllers>>PXIe-8130, PXI/CompactPCI>>Controllers>>PXIe-8130 RT, PXI/CompactPCI>>Controllers

Problem:
I would like to set up my PXIe-8130 controller so that it can boot into LabVIEW Real-Time, or as a dual-boot system with Windows.  Is this possible?

Solution:
In order to install the real-time operating system, or to make it a dual-boot controller, the PXIe-8130 must have a Parallel ATA (PATA) hard drive.  To check whether your 8130 controller comes with a parallel ATA (PATA) or serial ATA (SATA) hard drive, refer to the following table:

Controller Factory Configuration

O/S

 Hard Drive

PXIe-8130

Windows

SATA

PXIe-8130
(Extended Temperature and
24/7 Operation Option)

Windows

 PATA

PXIe-8130 RT

Real-Time

PATA



If your controller does not have a PATA harddrive from its factory configuration described above, the necessary hardware to install a PATA harddrive is not present, meaning one cannot replace the existing SATA drive with a PATA drive.

It is important to note that the LabVIEW Real-Time operating system will not support any PXIe-8130 controllers with a SATA hard drive for two reasons:
  • LabVIEW Real-Time (RT) versions prior to 8.5 do not support SATA hard drives. 
  • LabVIEW RT 8.5 and onwards only supports SATA hard drives in Advanced Host Controller Interface (AHCI), and AHCI is not supported on the chipset used by the PXIe-8130 controllers
Once it is determined that an RT-compatible PATA hard drive is present, the hard drive should be formatted as FAT32 for LabVIEW Real-Time to be installed.  You can learn more about this installation process by referring to KnowledgeBase 44A9Q1PB: How Can I Make My PXI Controller a Real-time Target?  Alternatively, the PXIe-8130 supports LabVIEW Real-Time 8.5.1 or higher with the Reliance File System.  For more information on installing Reliance, see KnowledgeBase 4JKCTSQ0: How do I install Reliance on my RT PC or PXI Target?

Related Links:

KnowledgeBase 2CMF6CZ8: Dual Boot PXI RT Controller for Windows and RTOS
KnowledgeBase 44A9Q1PB: How Can I Make My PXI Controller a Real-time Target?
KnowledgeBase 4JKCTSQ0: How do I install Reliance on my RT PC or PXI Target?

Products & Services: NI PXIe-8130
Products & Services: NI PXIe-8130 RT



Attachments:





Report Date: 03/28/2008
Last Updated: 03/19/2009
Document ID: 4JRGF44N

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit