Error 10003 occurs when performing SCXI_SCAN_Config or SCXI_SCAN_Setup.

Primary Software: LabVIEW Development Systems>>Professional Development System
Primary Software Version: 8.0
Primary Software Fixed Version: N/A
Secondary Software: Driver Software>>NI-DAQmx
Hardware: SCXI>>Chassis>>SCXI-1000

Problem: Why do I get error -10003 when I call SCXI_SCAN_Config or SCXI_SCAN_Setup with a call library function node?

Solution: The values passed into these functions, particularly the DAQboard and modeFlag parameters, should be passed as "Value", not "Pointer to Value."