Why are the digital I/O port numbers on my 6025E not the same as the manual when using Traditional-DAQ? Primary Software: LabVIEW Development Systems>>Full Development SystemPrimary Software Version: 8.2 Primary Software Fixed Version: N/A Secondary Software: Utility Software>>Measurement & Automation Explorer
Problem: When using the extended DIO ports of the 6025E in Traditional-DAQ, the port numbers do not match up to the documentation. In the February 2007 E series user manual in the section "100-50-50-Pin Extended DIO I/O Connector Pinout" on page B7, the ports are listed as 0,1,2,3, but these actually match up to ports 0,2,3,4 in Traditional-DAQ. The ports are correct in DAQmx. Solution: This manual is meant to contain DAQmx-specific information where applicable. As written in the manual introduction:
The E Series User Manual contains information about using the National The older E Series Help file (.chm) contains Traditional-DAQ info. The newest documentation always matches DAQmx terminal names. Here are the port numbers for the 6025E in DAQmx and the corresponding port numbers in Traditional-DAQ.
Related Links: Knowledgebase 2GIICLDJ: Error -10007 When Using the Digital Line Functions With E-Series Devices Attachments:
Report Date: 04/10/2007 Last Updated: 04/11/2007 Document ID: 489C7K3U |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||