Error -10403 When Running DIGPrt.vbp Example with PC-516Primary Software: Driver Software>>NI-DAQPrimary Software Version: 5.1 Primary Software Fixed Version: 6.0 Secondary Software: N/A Hardware: Legacy DAQ Devices>>Multifunction DAQ>>PC-516
Problem: I am running the DIGPrt.vbp example that ships with NI-DAQ (versions prior to 6.0). It returns error -10403 (Device Support Error) when using a PC-516. Solution: The PC-516 has two 4-bit ports: one input and one output. The ports cannot be configured any other way. This example program calls DIG_Prt_Config, which is illegal for this device. Ports cannot be configured for this device. To use this example with the PC-516, you can comment out this line and the NIDAQErrorHandler line after it. Also, use port number 1 as your input port. Related Links: Attachments:
Report Date: 11/10/1997 Last Updated: 06/18/2004 Document ID: 139C0405 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||