當我要執行FPGA的VI時,出現Error -63030



主要軟體:
主要軟體版本: 1.0
主要軟體修正版本:
次要軟體: N/A

問題: 當我執行我的FPGA VI時,我得到了以下的錯誤訊息:

Error -63040

NI-RIO FPGA Communications Framework: (Hex 0xFFFF09C0) A connection could not be established to the specified remote device. Ensure the device is on and accessible via the network, and that it is listening on the correct port.

我要怎麼解決?

解答:

這是因為 NI-RIO 驅動程式的版本與host電腦上的版本不相符。 您需要更新NI-RIO FCF 的驅動程式以解決此問題。 參閱 MAX 的 Help 以得到更新 CompactRIO 軟體的指示:

  1. 開啟 Measurement & Automation Explorer.
  2. 按下 F1 以打開 MAX Help.
  3. 展開 Measurement & Automation Explorer Help » MAX Remote Systems Help » LabVIEW Real-Time Target Configuration » Adding or Removing Software » Using the LabVIEW Real-Time Software Wizard.


相關連結:

附加檔案: