Problem:
I am getting an error that tells me I am missing one of the IVA or IVB subVIs. What are IVA and IVB subVIs, and where can I find them?

Solution:
An IVA subVI is a VI that was created by performing a "Create LabVIEW VI..." from Vision Assistant.

An IVB subVI is a VI that was created by performing a "Migrate Inspection to LabVIEW..." from Vision Builder for Automated Inspection.

If you get an error telling you that you are missing one of the IVA or IVB subVIs, you can find the specific VI by searching your hard drive for it, or you can find them in the following directories, and then in the .llb related to the name of the missing VI:

IVA:

  • C:\Program Files\National Instruments\Vision Assistant x.x\CG\IVA Templates LVxx-Visionxx.llb

IVB:

  • C:\Program Files\National Instruments\Vision Builder AI x.x\LV\SubVIs

Note: x.x is the version of your software.

You should also consider upgrading your version of your software so that you don't get the missing subVI error when generating LabVIEW code from Vision Assistant or from Vision Builder for Automated Inspection. You can also try reinstalling your Vision Assistant or Vision Builder for Automated Inspection software and make sure there is support for your version of LabVIEW.

Related Links:
Migrating VBAI 2.6.1 Script to LabVIEW Generates VI that Will Not Execute Properly
Vision Assistant / VBAI Code Migration to LabVIEW 7.1

Attachments:





Report Date: 04/05/2007
Last Updated: 04/06/2007
Document ID: 484EQ9HB

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit