1 ratings:
 2 out of 5   

How Do I Remotely Toggle the PXI-1000B Power Switch During Recharging?



Hardware: PXI/CompactPCI>>Chassis>>PXI-1000B

Problem:
I have noticed that a recharging battery power source will not trigger the chassis to restart when the power switch is left in the ON position as the battery passes the low voltage threshold. It is necessary to toggle the power switch from ON to Standby and back to ON in order to get the chassis to restart. How can I accomplish this remotely?

Solution:
The PXI 1000B has a remote inhibit feature that serves the same purpose as toggling the power switch from ON to Standby back to ON. In order to take advantage of this feature, please reference the section titled Remote Power Monitoring and Inhibiting Interface of the PXI-1000B User Manual linked at the end of this document.

Related Links:
Product Manuals: PXI-1000B User Manual and Specifications
KnowledgeBase 4V17IA1V: Remote Power of a PXI Chassis

Attachments:





Report Date: 01/31/2003
Last Updated: 04/08/2010
Document ID: 2TUD546W

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit