LabVIEW SignalExpress Crashes During Data AcquisitionPrimary Software: LabVIEW SignalExpress>>Development SystemPrimary Software Version: N/A Primary Software Fixed Version: N/A Secondary Software: N/A
Problem: My SignalExpress project crashes while running a DAQmx acquire. What are the available workarounds? Solution: There are two basic causes for this crash. Both have been reported to the SignalExpress R&D team, and workarounds can be found below. Scenario 1: The project crashes when acquiring N-samples while recording. This crash can be avoided by changing the "Prepare log data for viewing” option.
This crash can be avoided by eliminating the timeout error, or by changing the "Prepare log data for viewing” option (please refer to the steps above). To eliminate the timeout, ensure that the timeout value allows enough time for the DAQmx Acquire step to acquire all of the data. Timeout should be greater than Samples to Read divided by Sample Rate. For more information on DAQmx timeouts, please see the KnowledgeBase article Why Do I Get Error -200284 from my DAQmx Read VI? linked below. Related Links: KnowledgeBase 336EKTKD : Why Do I Get Error -200284 from my DAQmx Read VI? KnowledgeBase 4L18RHQ2: What are Valid Timeout Values for my NI DAQmx Task? Attachments:
Report Date: 10/13/2008 Last Updated: 02/12/2010 Document ID: 4QCADLF2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||